Cable, rod or coaxial sensor. Its robust, mechanical design and the second process seal, the Second Line of Defense, protect the sensor for demanding measurement tasks. Process temperature: -196 ... 450° C; process pressure: -1 … 400 bar
The VEGAFLEX 86 level sensor measures maintenance-free all liquids under extreme pressure and temperature conditions. Even in applications with buildup, foam generation and condensation, the sensor delivers precise and reliable measured values. In saturated steam applications, a special reference probe ensures a density-independent measurement. The VEGAFLEX 86 offers an economical level and interface measurement for your application.
Your BenefitSpecification
VEGAFLEX 86
Measuring range - Distance
75 m [Meter - Foot]
Process temperature
-196 ... 450 °C [°C - °F]
Process pressure
-1 ... 400 bar [Bar - kPa - psi]
Accuracy
± 2 mm
Version
Coax version ø 21.3 mm with multiple hole
Coax version ø 42.2 mm with single hole
Coax version ø 42.2 mm with multiple hole
Exchangeable rod ø 16 mm
Exchangeable cable ø 2 mm with gravity weight
Exchangeable cable ø 4 mm with gravity weight
Exchangeable cable ø 2 mm with centering weight
Exchangeable cable ø 4 mm with centering weight
Materials, wetted parts
316L
Alloy C22 (2.4602)
316
Threaded connection
≥ G¾, ≥ ¾ NPT
Flange connection
≥ DN25, ≥ 1"
Seal material
FFKM
graphit and ceramic
Protection rating
IP66/IP68 (0,2 bar)
IP66/IP67
IP66/IP68 (1 bar)
Housing material
Plastic
Aluminium
Stainless steel (precision casting)
Stainless steel (electropolished)
Output
Profibus PA
Foundation Fieldbus
Two-wire: 4 … 20 mA/HART
Modbus
Four-wire: 4 … 20 mA/HART
Ambient temperature
-40 ... 80 °C
Approvals
Scope
ATEX / EUROPE
IEC / WORLDWIDE
CSA / USA AND CANADA
FM / USA AND CANADA
Display & adjustment
Adjustment
PLICSCOM
PC, PACTware and DTM
HART-Communicator
Software (e. g. AMS™, PDM)
Indication
Display/adjustment module PLICSCOM
VEGADIS 81
VEGADIS 82
Level and interface measurement at high pressure and high temperature
The robust guided radar sensor VEGAFLEX 86 measures the level and interface of liquids at high process temperatures and pressures in tanks of all types. It operates independently of media properties such as density or dielectric constant in widely different vessels, bypasses or boilers. The robust mechanical design and second seal (second line of defense) protect the sensor while it performs demanding measurement tasks in the chemical, petrochemical, energy and oil/gas sectors, e.g.
Debutanizer
Level measurement and point level detection in the debutanizer
Deethanizer
Level measurement and point level detection in the deethanizer
Preflash drum
Preflash drum
Reboiler
Level measurement in the reboiler
Resources