From DK > 1.5, from thread ½", universal connection G1" for hygiene adapter, M12, valve plug, transistor output, IO-Link, wireless operation, Ex and hygiene approvals, tube version, up to 1 m
VEGAPOINT 23 is a limit switch with remote switching point for detection of water-based liquids. The optional universal connection for hygiene adapters ensures reduced installation effort and leaner stock keeping and perfectly meets the requirements for hygienic processes in the food, beverage and pharmaceutical industries. It can be used without adjustment in the application. With IO-Link, it offers continuous digital data transmission.
Your benefitSpecification
VEGAPOINT 23
Measuring range - Distance
- [Meter - Foot]
Process temperature
-40 ... 115 °C [°C - °F]
Process pressure
-1 ... 64 bar [Bar - kPa - psi]
Materials, wetted parts
316L
PEEK
Hygenic fittings
Clamp ≥ 2", DN50 - DIN32676, ISO2852
Clamp ≥ 1" - DIN32676, ISO2852
Clamp ≥ 1½" - DIN32676, ISO2852
Slotted nut ≥ 1½", ≥ DN40 - DIN 11851
Slotted nut ≥ DN25 - DIN 11851
Slotted nut ≥ DN32 - DIN 11851
Seal material
EPDM
FKM
Protection rating
IP66/IP67
IP69
Output
Transistor (NPN/PNP)
IO-Link
Ambient temperature
-40 ... 70 °C
Threaded connection
≥ G½, ≥ ½ NPT
Approvals
Scope
ATEX / EUROPE
IEC / WORLDWIDE
CSA / USA AND CANADA
Display & adjustment
Adjustment
Smartphone / Tablet / PC via Bluetooth
PC, PACTware and DTM, IODD
Indication
360° status display
Wort kettle
Pressure and point level measurement in the wort kettle and in the hops dissolver
Batching tank for milk cultures
Level measurement and point level detection in the batching tank
Storage container for rennet
Level measurement and point level detection in the storage container
Pump room
Pressure monitoring and flood protection in the pump room
Resources
Our Brands