It detects the limit level reliably and with millimetre accuracy directly at the mounting position. Numerous process fittings, approvals as well as housing and electronics versions.
The VEGASWING 61 is a universal level switch for use in all liquids. Independent of the mounting position, it detects reliably with millimetre accuracy the limit level. The instrument can be used as empty or full detector, as approved overfill protection, dry run protection or pump protection in vessels and pipelines. The VEGASWING 61 offers maximum reliability in a wide application range.
Specification
VEGASWING 61
Measuring range - Distance
- [Meter - Foot]
Process temperature
-50 ... 250 °C [°C - °F]
Process pressure
-1 ... 64 bar [Bar - kPa - psi]
Threaded connection
≥ G¾, ≥ ¾ NPT
Materials, wetted parts
PFA
316L
Alloy C22 (2.4602)
Alloy 400 (2.4360)
ECTFE
Enamel
Version
Standard
Hygienic applications
with gas-tight leadthrough
with temperature adapter
Flange connection
≥ DN25, ≥ 1"
Hygenic fittings
Clamp ≥ 1" - DIN32676, ISO2852
Slotted nut ≥ 1½", ≥ DN40 - DIN 11851
Varivent ≥ DN25
hygienic fitting F40 with compression nut
SMS 1145 DN51
SMS DN38
Hygienic fittings ≥ DN25 - DIN11864-1-A
Hygienic flange connection DIN11864-2-A; DN60(ISO)ø60,3
SMS socket piece DN38 PN6
Housing material
Plastic
Aluminium
Stainless steel (precision casting)
Stainless steel (electropolished)
Protection rating
IP66/IP67
IP66/IP68 (1 bar)
IP65
Seal material
no media contact
Ambient temperature
-40 ... 70 °C
Output
Relay (DPDT)
Contactless electronic switch
Transistor (NPN/PNP)
Two-wire
NAMUR
Display & adjustment
Adjustment
Pluggable display module PLICSLED
Batching tank for ointments
Level and pressure measurement and point level detection in ointment production in batch mode
Cleaning agent storage tank of the CIP system
Level measurement and point level detection in the cleaning agent storage tank of the CIP system
Reaction vessel
Level and pressure measurement and point level detection in multi-product and multi-line production facilities
Reaction vessel with solvents
Level measurement and point level detection in mixing processes